| SPA9000 and SPA400 Disconnect Toneby Mark Vella-West 5 Mar 2008 Hey guys,
If you are having problems with the Linksys SPA400 disconnecting PSTN calls (or rather - not disconnecting PSTN calls after the caller has hung-up), try the following settings:
On the spa400 there is a hidden page.
http:///html/hide_cptone.htm
Enter in the following:
Tone on Fraction: 45
High Cutoff Frequency: 430
Low Cutoff Frequency: 420
First Tone on and off: 375
Second Tone on and off: 375
Repeat Count: 2
Press Submit.
Then Voice Tab (PSTN Settings), use the following for Australia:
Transmit Gain: 10db
Receive Gain: 0db
Impedence: 220 Ohms + (820 Ohms||120nF)
Tip/Ring Voltage: 3.1V
Operational Loop current min: 14mA
On-Hook Speed: 26ms (Australia)
DC Current Limiting: Disable
Caller ID: European
Tear Down FXO port when silence period detected: 120 sec
Worked a treat for our SPA9000 / SPA400 / SPA942's!